Updated CR-10 Max Configuration.h#981
Merged
thinkyhead merged 1 commit intoMarlinFirmware:import-2.1.xfrom Oct 22, 2023
DakotaCodes00:patch-1
Merged
Updated CR-10 Max Configuration.h#981thinkyhead merged 1 commit intoMarlinFirmware:import-2.1.xfrom DakotaCodes00:patch-1
thinkyhead merged 1 commit intoMarlinFirmware:import-2.1.xfrom
DakotaCodes00:patch-1
Conversation
Biggest fix is the Z_MIN_PROBE_PIN For some odd reason the CR-10 Max uses pin 19 for the BL Touch sensor pin and not the default Z- endstop pin or Z Probe Pin as defined in the ramps pin file. Previously used this config and the BL Touch never triggered, explicitly using pin 19 fixed the issue. I also just changed the machine name to be "CR-10 Max". Hope this helps, thanks to all the contributors who make Marlin Possible, YOU ROCK! :b
Contributor
|
Nice catch, thanks. |
Contributor
Author
|
@ellensp No problem, glad I was able to help :) |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Description
For some odd reason the CR-10 Max uses pin 19 for the BL Touch sensor pin and not the default Z- endstop pin or Z Probe Pin as defined in the ramps pin file.
Previously used this config and the BL Touch never triggered, explicitly using pin 19 fixed the issue.
I also just changed the machine name to be "CR-10 Max".
Hope this helps, thanks to all the contributors who make Marlin Possible, YOU ROCK! :b
Benefits
Related Issues