A modbus/RTU controller and daemon for the SDM72D Smart Meter.
On first start sdm72dc writes a configuration template to ~/.config/sdm72dc
ttydev /dev/ttyUSB0
stopbits 1
slaveid 1
mqtthost mqtt.host.org
mqttport 1883
mqttuser user
mqttpass ***
capath /etc/ssl/certs
publish0 0x34 smartmeter/power/total
publish1 0x0156 smartmeter/energie/total
publish2 0x0180 smartmeter/energie/resetable
reset_hh 7
E.g. on Debian/Ubuntu:
sudo apt install cmake libmodbus-dev libmosquitto-dev libssl-dev
mkdir build
cd build
cmake ..
make
- Download toolchain for ARM architecture from https://developer.arm.com/downloads/-/arm-gnu-toolchain-downloads
- Install toolchain
tar -xf arm-gnu-toolchain-*-x86_64-arm-none-linux-gnueabihf.tar.xz
# move it to your preferred location and create a symlink,
# e.g. ~/dev/arm-toolchain
- scp the sysroot to your build machine
rsync -ac root@<target>:/{lib,usr} ~/dev/arm-sysroot
-
Edit arm.cmake to point to the toolchain and sysroot
-
Cross compile for ARM