Rates of pyrolysis reactions are often described by two main terms, the rate constant
Keeping the sample temperature constant allows one to assess the reaction profile and thus facilitates the choice of the reaction model.
In terms of FDS this can be used to assess if the chosen model fits to the behaviour of the sample, recorded during isothermal TGA experiments.
Describe the solution you'd like
It would be nice if the functionality of the existing simplified TGA model TGA_ANALYSIS could be expanded such that isothermal TGA runs can easily be replicated.
Two extra parameters need to be added for the isothermal conditions, for example:
ISO_TEMP, provided in °C, the target temperature of the isothermal run (or maybe useTMPAsimilar to the initial temperature when using the constant heating rate)ISO_T_END, provided in seconds, used to stop the simulation, since they could run for long times at low temperatures when running for completion- [optional]
TIME_STEP, provided in seconds, to have some control over the resolution of the output
The output should basically be a CSV file like the existing one, providing time, sample temperature and the sample mass.