@xjikka xjikka commented Nov 15, 2026

Copy link
Copy Markdown
Contributor

Home Assistant discovery currently gives every energy-class sensor state_class: total_increasing. Several of them can decrease:

  • Energy Last Hour is a rolling sum over the stats period,
  • Energy Yesterday, 2 Days Ago and 3 Days Ago shift once a day and can go up or down (in BL twin mode the _b variants as well).

HA reads each decrease as a meter reset. The result:

  • a daily warning in the HA log:
    Entity sensor.xxx_energy_yesterday from integration mqtt has state class total_increasing, but its state is not strictly increasing. Triggered by state 7.827 (previous state: 8.436)
  • long-term statistics for these sensors that make no sense, because every "reset" adds the whole new value again.

Change: stat_cla: total_increasing is sent only for OBK_CONSUMPTION_TOTAL and OBK_CONSUMPTION_TODAY; the other energy sensors get no stat_cla. measurement would not work, because HA does not allow it with device_class: energy. Energy Today still works as expected, since HA handles its midnight reset as a new meter cycle. The check is on the sensor index, and both BL twin datasets use the same index, so it covers twin mode too.

The selftest Test_HassDiscovery expected total_increasing for energycounter_last_hour; it now checks the sensor without stat_cla.

Tested: HA 2026.10, 12 devices (BK7231N + BL0937, LN882H, BK7231N BL0942 twin). Energy Last Hour, Yesterday, 2 and 3 Days Ago come without stat_cla, Energy Total and Today keep total_increasing, other entities unchanged.

Yesterday's consumption changes once a day in both directions, so HA logs
'state class total_increasing, but its state is not strictly increasing'
and long-term statistics are wrong. Other energy sensors keep total_increasing.