The RS92 PTU data is described here:
https://brmlab.cz/project/weathersonde/telemetry_decoding
Frequencies of capacitive sensors can be measured as periods 1/freq. The RS92 PTU values can be approximately calculated as described in the lecture notes by Haeberli (2001):
https://www.file-upload.net/download-14470162/haeberli-convert.pdf.html
(probably for a predecessor of the RS92)
RS92 seems to use degree 5 polynomials to model the sensors, though for the two humidity sensors the upper two coefficients are zero.
In
2453b79
only the uncorrected values are calculated. Temperature and pressure are close enough.
The humidity sensors are heated in intervals (up to -60C/100hPa), however if the temperature difference is not constant, the temperature at the humidity sensor would have to be estimated depending on e.g. air temperature and air flow (climb rate). At lower temperatures and higher relative humidity the corrected relative humidity would be noticeably higher (applying e.g. Hyland/Wexler).
cf.
https://amt.copernicus.org/articles/7/4463/2014/ (amt-7-4463-2014)
https://www.vaisala.com/sites/default/files/documents/9781461439080-c1.pdf